    Utility of Capability Index and Quality Goal Index Ratio as Determinants of Quality Adherence in a Clinical Biochemistry Laboratory

    (ندگان)پدیدآور
    Kundu, SumanaMishra, AbhisekNandi, KajalGoswami, Binita
    Thumbnail
    نوع مدرک
    Text
    Original Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background and Objective: The measurement of the coefficient of variation (CV%) and bias has been used to check the precision and accuracy of laboratory-generated data. Indices like the capability index (Cp and Cpk) and the quality goal index ratio (QGI) take into account both CV and bias in order to categorize the results of various parameters, allowing for necessary actions to improve the outcomes of poorly performing parameters. Materials and Methods: This is a retrospective study, and data required for the study were extracted between January 2024 and June 2024 from a tertiary care government hospital in Delhi. The Cp, Cpk, and QGI were calculated, and six-month averages of these indices were taken to categorize the parameters. Results: For level 1 of internal quality control (IQC), the Cp indicated that sodium, chloride, urea, and low-density lipoprotein (LDL) performed marginally well, while potassium performed poorly. Meanwhile, the Cpk showed poor performance for sodium, potassium, chloride, urea, LDL, amylase, and lactate dehydrogenase (LDH). Sodium, potassium, chloride, urea, and creatinine had a QGI of 1.2, indicating that the bias was due to inaccuracy. For level 2 of IQC, Cp showed that sodium, chloride, LDH, and LDL were in the marginal range, and potassium performed poorly, while Cpk indicated poor performance for sodium, potassium, chloride, urea, protein, LDL, and LDH. Sodium, potassium, chloride, urea, and protein had a QGI of
    کلید واژگان
    Biochemistry
    Laboratory
    Clinical
    Bias
    Laboratory Methods

    شماره نشریه
    1
    تاریخ نشر
    2024-06-01
    1403-03-12
    سازمان پدید آورنده
    Department of Biochemistry, Maulana Azad Medical College, New Delhi, India
    Department of Biochemistry, Maulana Azad Medical College, New Delhi, India
    Department of Biochemistry, Maulana Azad Medical College, New Delhi, India
    Department of Biochemistry, Maulana Azad Medical College, New Delhi, India

    شاپا
    2371-770X
    URI
    https://dx.doi.org/10.30699/mmlj17.7.1.22
    http://modernmedlab.com/article-1-149-en.html
    https://iranjournals.nlai.ir/handle/123456789/1115808

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب