| dc.contributor.author | محمدجواد جعفری | en_US |
| dc.contributor.author | سپیده نوریان | en_US |
| dc.contributor.author | رضوان زنده دل | en_US |
| dc.contributor.author | محمد رضا مسعودی نژاد | en_US |
| dc.contributor.author | پروین سربخش | en_US |
| dc.contributor.author | علیرضا رحمتی | en_US |
| dc.contributor.author | امیر عباس مفیدی | en_US |
| dc.date.accessioned | 1399-12-08T21:48:20Z | fa_IR |
| dc.date.accessioned | 2021-02-26T21:48:20Z | |
| dc.date.available | 1399-12-08T21:48:20Z | fa_IR |
| dc.date.available | 2021-02-26T21:48:20Z | |
| dc.date.issued | 2015-06-28 | en_US |
| dc.date.issued | 1394-04-07 | fa_IR |
| dc.date.submitted | 2015-03-02 | en_US |
| dc.date.submitted | 1393-12-11 | fa_IR |
| dc.identifier.citation | (1394). ارتقای ایمنی و پیشگیری از مصدومیتها, 2(4), 321-328. doi: 10.22037/meipm.v2i4.8400 | fa_IR |
| dc.identifier.issn | 2345-2455 | |
| dc.identifier.issn | 2383-1901 | |
| dc.identifier.uri | https://dx.doi.org/10.22037/meipm.v2i4.8400 | |
| dc.identifier.uri | https://journals.sbmu.ac.ir/spip/article/view/8400 | |
| dc.identifier.uri | https://iranjournals.nlai.ir/handle/123456789/777855 | |
| dc.description.abstract | Background and Objective: Hydrogen sulfide is a hazardous gas which is fatal at high concentrations. The application of a spray tower to remove H2S from air is the simplest and cheapest method but its performance is under question. In this study, the performance of a spray tower in removing H2S from air as well as its pressure loss across the bed were investigated.Material and Methods: In this study a spray tower was used to remove H2S from air. H2S was injected to the tower at the range of 0-30 ppm. The volumetric flow rate of water as the scrubbing liquid was 2 lit/min and spraying was carried out by a pump with 21-35 Kg/cm2 head. The volumetric flow rate of air was supplied through a fan in the range of 2400-3000 lit/min. The pressure loss across the bed was monitored by an inclined manometer. H2S concentrations in air were measured using direct reading device. The results were analyzed using SPSS version 16.Results: The minimum pressure loss, 73.81±0.2887 Pa, was obtained at 1200 lit/min air flow rate without scrubbing liquid injected to the tower. The maximum pressure loss, 292.84±2.448 Pa, was experienced at 3000 lit/min air flow rate with 2 lit/min of water flow injected to the tower. The maximum removal efficiency, 70.53±1.5415%, was experienced at 1800 lit/min of air flow rate along with 15 ppm of H2S injected to the tower. Minimum removal efficiency, 47.74±0.9295%, was gained at 3000 lit/min of air flow rate and 30 ppm of H2S injected to the tower. Statistical t-test revealed that there is a significant difference between H2S removal efficiency with air flow rate and inlet concentration, also between pressure drop with air flow rate and the presence of water (p<0.001).Conclusion: The removal efficiency of spray tower decreases by increasing the input flow rate and input concentration of H2S. The performance of water as a scrubbing liquid in spray tower is not satisfactory thus, the application of water plus chemical scrubbing liquids is strongly recommended to be studied. | en_US |
| dc.format.extent | 447 | |
| dc.format.mimetype | application/pdf | |
| dc.language | English | |
| dc.language.iso | en_US | |
| dc.publisher | دانشگاه علوم پزشکی شهید بهشتی | fa_IR |
| dc.relation.ispartof | ارتقای ایمنی و پیشگیری از مصدومیتها | fa_IR |
| dc.relation.isversionof | https://dx.doi.org/10.22037/meipm.v2i4.8400 | |
| dc.subject | برج اسپری | en_US |
| dc.subject | سولفید هیدروژن | en_US |
| dc.subject | افت فشار | en_US |
| dc.subject | راندمان حذف | en_US |
| dc.title | The Performance of a Spray Tower in Scrubbing H2S from Air | en_US |
| dc.type | Text | en_US |
| dc.contributor.department | School of Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | MSc, School of Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | School of Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | Safety Promotion and Injury Prevention Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | School of Health, Tabriz University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | MSc, School of Health, Shahid Beheshti University of Medical Sciences, Tehran, Iran | en_US |
| dc.contributor.department | PhD candidate, School of Medicine, Tarbiat Modares University, Tehran, Iran | en_US |
| dc.citation.volume | 2 | |
| dc.citation.issue | 4 | |
| dc.citation.spage | 321 | |
| dc.citation.epage | 328 | |