• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات فارسی
    • نشریه پرستاری ایران
    • دوره 37, شماره 149
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات فارسی
    • نشریه پرستاری ایران
    • دوره 37, شماره 149
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Comparison of Arterial and Capillary Blood Glucose Measurement Accuracy Using a Glucometer in Diabetic Patients Undergoing Cardiac Surgery

    (ندگان)پدیدآور
    Mousavi, SoolmazAlizadeh, TaraJavadi Pashaki, NazilaKazemnejad Leili, EhsanGhorbani Vajargah, PooyanMajd Teymouri, Zahra
    Thumbnail
    نوع مدرک
    Text
    Research
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background & Aims Effective blood glucose measurement is crucial for reducing complications in diabetic patients. This study aims to compare the accuracy of measuring the capillary and arterial blood glucose levels using a glucometer in diabetic patients undergoing cardiac surgery. Materials & Methods This cross-sectional study was conducted on 73 patients with diabetes undergoing heart surgery at a specialized cardiology hospital in the north of Iran. A demographic/clinical questionnaire was first completed. Three types of blood glucose samples were taken from the patients: An arterial line sample sent to the laboratory, an arterial line sample monitored by a glucometer, and a capillary sample monitored by a glucometer. The average error and average absolute error of blood glucose measurement methods were calculated to record the error rate. Statistical analyses were conducted using  ANOVA, Bonferroni post hoc test, McNamar’s test, linear regression, and Bland-Altman plots to validate the accuracy of glucometer values against the lab results. Results Most of the participants were male (64.38%). Their mean age was 60.34±8.26 years. The mean absolute error between the laboratory glucose level and the arterial glucometer value was 11.12±13.16 mg/dL. The mean absolute error between the laboratory glucose level and the capillary glucometer value was 18.96±17.43 mg/dL, while the mean absolute error between the arterial and capillary glucometer values was 15.93±78.17 mg/dL. Statistical indicated a significant difference in the average absolute errors among the three methods (P
    کلید واژگان
    Blood glucose
    Diabetes mellitus
    Cardiac surgery
    nursing

    شماره نشریه
    149
    تاریخ نشر
    2024-08-01
    1403-05-11
    ناشر
    دانشگاه علوم پزشکی ایران
    سازمان پدید آورنده
    Department of Medical-Surgical Nursing, School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
    Department of Cardiology, Cardiovascular Diseases Research Center, Heshmat Hospital, School of Medicine Social Determinants of Health Research Center (SDHRC), Guilan University of Medical Sciences, Rasht, Iran.
    Department of Biostatistics, School of Health Road Trauma Research Center, School of Public Health, Guilan University of Medical Sciences, Rasht, Iran.
    Department of Biostatistics, School of Health Road Trauma Research Center, School of Public Health, Guilan University of Medical Sciences, Rasht, Iran.
    Department of Medical-Surgical Nursing, School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.
    Department of Medical-Surgical Nursing, School of Nursing and Midwifery, Guilan University of Medical Sciences, Rasht, Iran.

    شاپا
    2008-5923
    2008-5931
    URI
    https://dx.doi.org/10.32598/ijn.37.149.3454.1
    http://ijn.iums.ac.ir/article-1-3831-en.html
    https://iranjournals.nlai.ir/handle/123456789/1142108

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب