نمایش مختصر رکورد

dc.contributor.authorRafeie, Raminen_US
dc.contributor.authorEftekhari Yazdi, Mohammaden_US
dc.contributor.authorNakhaee, Kooroshen_US
dc.contributor.authorKhorramymehr, Siamaken_US
dc.date.accessioned1402-04-13T18:30:58Zfa_IR
dc.date.accessioned2023-07-04T18:31:00Z
dc.date.available1402-04-13T18:30:58Zfa_IR
dc.date.available2023-07-04T18:31:00Z
dc.date.issued2022-12-01en_US
dc.date.issued1401-09-10fa_IR
dc.identifier.citation(1401). مجله ارگونومی, 10(3), 190-199.fa_IR
dc.identifier.issn1735-1960
dc.identifier.issn2345-5365
dc.identifier.urihttp://journal.iehfs.ir/article-1-915-en.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/1000064
dc.description.abstractObjectives: Investigating the effective factors in controlling and increasing stability due to weakening of the balance parts of the body in the elderly with osteoporosis, in order to prevent falling is of particular importance, so in this study, the effect of anti-slip flooring in the stimulation of the somatosensory part of the sole of the foot to improve postural stability and gait balance has been evaluated in the elderly with osteoporosis. Methods: 22 elderlies participated (11 elderly women with severe osteoporosis,11 healthy elderly women) in this study in two static and dynamic condition on three different surfaces including sponge non-slippery flooring (FL), PVC patterned non-slippery flooring (SF) and control surface (CO). In the static part, each participant was standing on the force plate for 30 seconds with eyes open and eyes closed. The values of the length, sway and average velocity of the anterior-posterior and internal-external center of pressure of the foot were measured. In the dynamic part, each participant walked at a selected speed on different surfaces and the values of the normalized step and stride length, step width, step and stride time, and average step and stride velocity were measured. Results: PVC non-slippery flooring (SF) and control surface (CO) reduced all postural stability and gait variables (P < 0.05) in osteoporosis and healthy elderly than soft Sponge Surface (SF). Moreover, all postural stability variable and spatial and temporal gait parameters were significantly more in the osteoporosis elderly than in healthy elderlies (P < 0.05). Moreover, anterior-posterior mean velocity in open-eyed state significantly reduced in both elderly groups than close-eyed state (P < 0.05). Conclusion: Stiff and patterned surfaces are more effective than soft spongy surfaces in stimulating the somatosensory part of the foot sole to improve stability in both osteoporotic and healthy elderly groups. The results of this study may be helpful to understand the characteristics of the elderly while walking and standing on non-slippery flooring in different environments and the ergonomic design of the environment in order to reduce slips and falls and as a result possible fracture in the elderly with severe osteoporosis. In addition, observation of instability between the elderly with osteoporosis and healthy suggests the need for further investigation and the use of auxiliary exercises to correct and improve stability.en_US
dc.format.extent1177
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherانجمن ارگونومی و مهندسی عوامل انسانی ایرانfa_IR
dc.relation.ispartofمجله ارگونومیfa_IR
dc.relation.ispartofJournal of Ergonomicsen_US
dc.subjectFloorcoveringen_US
dc.subjectPostural balanceen_US
dc.subjectGait variabilityen_US
dc.subjectOsteoporosisen_US
dc.subjectElderlyen_US
dc.subjectErgonomicsen_US
dc.subjectBiomechanicsen_US
dc.titleThe Effect of Non-Slippery Flooring on Postural Stability and Gait Parameters in Severe Osteoporosis Elderlyen_US
dc.typeTexten_US
dc.typeResearchen_US
dc.contributor.departmentDepartment of Biomechanics, Faculty of Medical Sciences and Technologies, Science and Research Branch, Islamic Azad University, Tehran, Iranen_US
dc.contributor.departmentDepartment of Mechanical Engineering, Central Tehran Branch, Islamic Azad University, Tehran, Iranen_US
dc.contributor.departmentDepartment of Mechanic and Biomedical Engineering, School of Sciences and Technologies, Eslamshahr Branch, Islamic Azad University, Tehran, Iranen_US
dc.contributor.departmentDepartment of Biomechanics, Faculty of Medical Sciences and Technologies, Science and Research Branch, Islamic Azad University, Tehran, Iranen_US
dc.citation.volume10
dc.citation.issue3
dc.citation.spage190
dc.citation.epage199


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد